GEARED MOTOR SF-PRP 80M~225S FOOT TYPE

GEARED MOTOR SF-PRP 80M~225S FOOT TYPE Series (Outdoor Waterproof Motor) P9
Can be sued safety outdoors, even under weather conditions such as rain,wind,snow,etc.
“Super Line Premium Series SF-PRP” demonstrates the full potential of Mitsubishi high-efficiency technology. While maintaining the ease of use of general-purpose motors. With proprietary steel frame technology, Mitsubishi Electric will continue to develop and sell products that comply with global high efficiency regulations.

SF-PRP 80M~225S FOOT TYPE
TOTALLY ENCLOSED FAN-COOLED TYPE, IP55 DEGREES OF PROTECTION (Outdoor Dust & Water jet proof Motor)

Features

Dust & Water jet proof performance (IP55 Degrees of protection)

Passed the dust and the water spray test for compliance with JIS C 4034-5, so it can be used with confidence in locations exposed to large quantities of water.

Construction

The main parts of the motor are the same as SF-PR, but in order to provide stable operation under even more severe conditions than those of the outdoor type, special consideration is given to the following.

  • Shaft through part

Both the load side and the anti-load side are provided with a fringer or V-ring that rotate together with the shaft so as to prevent water leaking into the motor.
In addition, end covers are mounted on the load side and anti-load side to further improve the dust & water jet proofing.
* The vertical flange type motor has a fringer or V-ring mounted on the 
anti-load side, while the horizontal flange type motor has a fringer or V-ring and end cover mounted on the anti-load side. Note that the shaft through part does not have a waterproof structure since the load side of the vertical flange and horizontal flange type motors is incorporated into the mating machine.

  • Terminal box
Terminal boxes with frame numbers from 80 to 180 are made of steel plate, and those with number 200 or higher are made of cast iron. To ensure complete dust & water jet proof structure, a gasket is provided between the base and the cover. 
Terminal block connection method is used for frame numbers 80 to 132, and lead wire connection method is used for frame numbers 160 and higher. 
Also, since the external cable entry port is parallel pipe threaded, conduits and watertight cable glands can be installed.
* When changing the direction of the cable entry port, be sure to firmly seal the piping so as to prevent the ingress of water, dust, etc.

Load side shaft through structure on outdoor dust & water jet proof motor

  • Mating part
Liquid gasket is applied to the frame and bracket mating section to improve the dust & water jet proof performance.
Reapply the liquid gasket when disassembling and reassembling the motor.
 
  •  Installation method
Dust & water jet proof performance is provided in the standard installation direction shown in the dimensional drawings; inquire in the case of non-standard installation.
 
  • Coating
Coated with paint that is excellent in weather resistance, saltwater resistance, and chemical resistance.
 

Terminal box detailed view

Dimensional Drawings

SF-PRP Outdoor Dust & Water jet proof Motor

Dimensoin Table

Frame
Number
Thermal
Class
Output
(kW)
Figure
Number
Dimensions (mm)
Motors
4 Pole A B C* D E F G H I J K KA KD KG KL(KL)
80M 120
(E)
0.75 1 122 97 80 162 62.5 50 3.2 166  -  -  - 39.5 PF 3/4 109 168
90L 1.5 143 116.5 90 184 70 62.5 4 191  -  -  - 53 PF 3/4 123 173
100L 2.2 2 173 132 100 207 80 70 6.5 203.5 230 40 45 65 PF 3/4 136 185
112M 3.7 181 139 112 228 95 70 6.5 226 253 40 45 69 PF 3/4 151 196
132S 130
(B)
5.5 211.5 158 132 266 108 70 6.5 265 288 40 45 75 PF 1 177 223
132M 7.5 230.5 177 132 266 108 89 6.5 265 288 40 45 94 PF 1 177 223
160M 11 3 252 209 160 318 127 105 8 316 367 50  - 105 PF 1 1/4 116 274
160L 15 274 231 160 318 127 127 8 316 367 50  - 17 PF 1 1/4 116 274
180M 18.5,22 292.5 237.5 180 363 139.5 120.5 8 359 410 50  - 127 PF 1 1/2 140 296
180LD 155
(F)
30 4 349.5 258.5 180 406 139.5 139.5 11 381  - 58  - 184 PF 2 432 (487)
200LD 37,45 355 282 200 446 159 152.5 11 421  - 64  - 145 PF 2 487 (567)
225S 55 425 282 225 446 178 143 11 446  - 70  - 205 PF 2 1/2 512 (592)
Frame
Number
Dimension (mm) Bearing Number Approximate
Unloaded Mass(kg)
Motors Shaft End
L M ML N X XB Z Q QK R S T U W Load Side Anti-Load Side 4 Poles
80M 262 160  - 125 15 50 9 40 32 140 19j6 6 3.5 6 6204ZZ 6204ZZ 14
90L 311.5 175  - 150 15 56 9 50 40 168.5 24j6 7 4 8 6205ZZ 6205ZZ 21
100L 366 200 212 180 4 63 12 60 45 193 28j6 7 4 8 6206ZZ 6205ZZ 31
112M 381 230 242 180 4 70 12 60 45 200 28j6 7 4 8 6206ZZ 6206ZZ 42
132S 450.5 256 268 180 4 89 12 80 63 239 38k6 8 5 10 6308ZZ 6207ZZ 60
132M 488.5 256 268 4 89 12 80 63 258 38k6 8 5 10 6308ZZ 6207ZZ 69
160M 575 310  - 254 4 108 14.5 110 90 323 42k6 8 5 12 6309ZZ 6308ZZ 100
160L 619 310  - 298 4 108 14.5 110 90 345 42k6 8 5 12 6309ZZ 6308ZZ 120
180M 644 335  - 285 4 121 14.5 110 90 351.5 48k6 9 5.5 14 6311ZZ 6310ZZ 150,155
180LD 720 341  - 323 4 121 14.5 110 90 370.5 55m6 10 6 16 6312ZZ 6311ZZ 245
200LD 780.5 390  - 361 4 133 18.5 140 110 425.5 60m6 11 7 18 6315ZZ 6312ZZ 300,325
225S 857 428  - 342 4 149 18.5 140 110 432 65m6 11 7 18 6315ZZ 6312ZZ 380

*The vertical tolerance for the shaft center is °-₀.₅

Since outline drawings are shown by representative models, some appearances may silghtly differ depending on the frame number.

Make sure to inquire when requiring exact external dimensions, since the external dimensions may be partially modified due to the refinement process, etc.

For frame number 180 LD, the terminal box is on top of the motor, not side-mounted. (Differ from 180M.)